Performance Test Results
Project |
Quality indicator |
Quality indicator |
Quality indicator |
Quality indicator |
Quality indicator |
Quality indicator |
Quality indicator |
Quality indicator |
Model |
68 |
100 |
150 |
220 |
320 |
460 |
680 |
1000 |
Kinematic viscosity (40℃) /(mm 2 /s) |
61.2~74.8 |
90.0~110 |
135~165 |
198~242 |
288~352 |
414~506 |
612~748 |
900~1100 |
Appearance |
transparent |
transparent |
transparent |
transparent |
transparent |
transparent |
transparent |
transparent |
Kinematic viscosity ( 10 0℃)/(mm2 / s) |
Report |
Report |
Report |
Report |
Report |
Report |
Report |
Report |
Pour point/℃ not higher than |
-12 |
-12 |
-9 |
-9 |
-9 |
-9 |
-5 |
-5 |
Flash point (open)/℃ not less than |
180 |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
Moisture (mass fraction) % not more than |
trace |
trace |
trace |
trace |
trace |
trace |
trace |
trace |
Mechanical impurities (mass fraction) % not more than |
0.02 |
0.02 |
0.02 |
0.02 |
0.02 |
0.02 |
0.02 |
0.02 |
Copper strip corrosion (100 ℃ , 3h)/level No more than |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
Liquid phase corrosion test ( 24h ) |
Rust-free |
Rust-free |
Rust-free |
Rust-free |
Rust-free |
Rust-free |
Rust-free |
Rust-free |
Foaming properties (foaming tendency/foaming stability) (ml/ml) |
50/0
50/0
50/0 |
50/0
50/0
50/0 |
50/0
50/0
50/0 |
50/0
50/0
50/0 |
50/0
50/0
50/0 |
75/10
75/10
75/10 |
75/10
75/10
75/10 |
75/10
75/10
75/10 |
Extreme pressure performance (Timken test machine method) |
267(60) |
267(60) |
267(60) |
267(60) |
267(60) |
267(60) |
267(60) |
267(60) |
Demulsibility (82℃) |
2.0
1.0
80.0 |
2.0
1.0
80.0 |
2.0
1.0
80.0 |
2.0
1.0
80.0 |
2.0
1.0
80.0 |
2.0
4.0
50.0 |
2.0
4.0
50.0 |
2.0
4.0
50.0 |
Shear stability (gear machine method) |
Within the viscosity grade range |
Within the viscosity grade range |
Within the viscosity grade range |
Within the viscosity grade range |
Within the viscosity grade range |
Within the viscosity grade range |
Within the viscosity grade range |
Within the viscosity grade range |
Four-ball machine test |
2450(250) 441(45)
0.35 |
2450(250) 441(45)
0.35 |
2450(250) 441(45)
0.35 |
2450(250) 441(45)
0.35 |
2450(250) 441(45)
0.35 |
2450(250) 441(45)
0.35 |
2450(250) 441(45)
0.35 |
2450(250) 441(45)
0.35 |
Sediment control, direct heating by electric heating rod, 120℃*460h |
No tar on the heating rod, no sediment in the oil, no staining on the utensils |
No tar on the heating rod, no sediment in the oil, no staining on the utensils |
No tar on the heating rod, no sediment in the oil, no staining on the utensils |
No tar on the heating rod, no sediment in the oil, no staining on the utensils |
No tar on the heating rod, no sediment in the oil, no staining on the utensils |
No tar on the heating rod, no sediment in the oil, no staining on the utensils |
No tar on the heating rod, no sediment in the oil, no staining on the utensils |
No tar on the heating rod, no sediment in the oil, no staining on the utensils |
Carrying capacityGear machine test /failure level not less than |
12 |
12 |
12 |
>12 |
>12 |
>12 |
>12 |
>12 |